TM 11-6625-3041-12/TO 33A1-8-908-1
1-14. EQUIPMENT DATA (cont)
Internal
Internal data rate
Data Rate
(MASTER position of
TIMING switch) is
set by the 21-
position DATA RATE
switch. This switch
is grouped into
three families
(576, .6-32, and
Each family uses a different type of connector.
128-4608).
576 Family:
Data rate 576 kb/s.
.6-32 Family:
Data rate 0.6, 1.2, 2.4, 4.8, 9.6, 16, and 32 kb/s.
128-4608 Family: Data rate 128, 144, 256, 288, 512, 576, 1024,
1152, 1536, 2048, 2304, 4096, and 4608 kb/s.
External data rate (LOOPED or STA CLK position of TIMING switch)
External
Data Rate
is set by frequency of external signal. Input and output
characteristics are those of the 128-4608 family (balanced NRZ).
Any frequency from 2 kHz thru 4915.2 kHz can be applied; in par-
ticular 2 kHz, 16 kHz, and 4915.2 kHz.
The 2 kHz and 16 kHz inputs can be applied to either the
BALANCED TMG IN connector (TIMING set to LOOPED) or STA CLOCK
connector (TIMING set to STA CLK). The 4915.2 kHz input can
only be applied to the STA CLOCK connector (TIMING set to STA
CLK).