TM
11-6625-3041-12/TO
33A1-8-908-1
3-11. TROUBLESHOOTING PROCEDURE (cont)
If DATA IN or TMG IN indicator does not light:
Remove LOGIC access cover (refer to para 3-16) and note which
card contains a lit fault indicator. Replace that card and
repeat step 7.
If no card contains a lit fault indicator, possible cause is
Receive 1 card A5.
step 7.
If replacement card does not provide proper indication, refer
SG-1139 to Direct Support Maintenance.
3-23