3-11. TROUBLESHOOTING PROCEDURE (cont)
If BER indications are improper:
Remove LOGIC access cover (refer to para 3-16) and note which
card contains a lit fault indicator. Replace that card and
repeat step 14.
If no card contains a lit fault indicator, possible cause is
Receive 2 card A6. Replace (refer to para 3-16), and repeat
step 14.