TM 11-6625-3041-12/TO 33A1-8-908-1
3-11. TROUBLESHOOTING PROCEDURE (cont)
This step checks the following:
Step
16
Receive 2 card . . . BER Duration Counter 104 and 2 x 105
cont
outputs
Red Error Count 10 output
Yellow Error Count 2 output
If any BER indication is improper:
Remove LOGIC access cover (refer to para 3-16) and note which
card contains a lit fault i n d i c a t o r . Replace that card and
repeat step 16.
If no card contains a lit fault indicator, possible cause is
Receive 2 card A6. Replace (refer to para 3-16), and repeat
step 16.
3-37