TM 11-6625-3041-12/TO 33A1-8-908-1
3-17. POWER SUPPLY CARD REPLACEMENT (cont)
Removal
Swing out lever
q
on bottom of
card to dis-
engage card
from connector.
Carefully pull
out card.
Visually inspect
card for defects
such as warpage,
crackes, or broken
portions, exces-
or shorted tracks,
and loose, missing,
or charred compo-
nents.
q Aline
card in slot
Replacement
and carefully push
in. As card be-
gins to engage,
lever will begin
to move
in.
q When
card is
properly in place,
swing in lever to
engage card in
connector.