TM 3-1040-281-20&P
2-9. M288 MOUNTING KIT (CONT).
h. Strainer Assembly/Ball Valve.
WARNING
Fog oil is very slippery. Cleanup
all spills immediately to prevent
injury to personnel. Do not drain
fog oil near open flames or while
smoking.
NOTE
Adapters, valves, elbows, and
strainer are removed and
installed on both sides of fog oil
tank assembly the same way.
Hoses may contain fog oil. Have
a suitable container available.
a. Loosen fog oil hose clamps (1) and pull
hoses (2 and 3) from adapters (4 and 5) on
fog oil tank. Drain hoses into a container.
b. Remove adapters (4 and 5), valves (6),
elbows (7) and strainer assembly (8) as
required for replacement.
c. Install strainer assembly (8), elbow (7),
valve (6), and adapter (4) in fog oil tank
supply port.
d. Install valve (6), elbow (7), and adapter (5) in
fog oil tank return port.
e. Reconnect fog oil inlet hose(2) to fog oil
tank supply adapter (4). Reconnect fog oil
exhaust hose (3) to fog oil tank return
adapter (5). Tighten fog oil hose clamps (1).
2-24