TM 3-1040-281-20&P
2-11. FOG OIL TANK ASSEMBLY (CONT).
a. Fog Oil Tank and Insulating Pads (Cont).
lNSPECTION/REPAIR
a. Inspect base plate pad (21), forward restraint pad (22), side restraint pads (23), top restraint pad (24) and
rear restraint pad (25).
c. Lift edge of pad with sharp tool.
d. Remove pad completely from restraint mounting surface.
WARNING
Prolonged breathing of trichloroethane vapors may cause injury to the lungs, heart, liver, and/or
kidneys. Use only in a well ventilated area. Do not use on hot surfaces. Wear neoprene gloves.
e. Clean restraint mounting surface with trichloroethane and rags.
f. Apply thin coat of adhesive to pad and mounting surface. Allow to dry for 10 to 20 minutes, then press
surfaces together.
2-28