TM 3-1040-281-20&P
2-12. FOG OIL TANK (CONT).
b. Sight Indicator.
REMOVAL/lNSTALLATION
WARNING
Fog oil is very slippery. Cleanup all spills
immediately to prevent injury to person-
nel. Do not drain fog oil near open flames
or while smoking.
NOTE
Fog oil level in tank should be below sight
indicator to be replaced.
Drain fog oil into suitable container. If
a. Remove sight indicator (1) from fog oil tank (2). Use
cleaner to free up indicator if necessary.
b. Clean threads in fog oil tank with a rag.
c. Coat threads of sight indicator (1) with sealing com-
pound.
d. Install sight indicator (1) in fog oil tank (2) and
secure.
c. Plug Valve.
REMOVAL/lNSTALLATION
WARNING
Fog oil is very slippery. Clean up all
spills immediately to prevent injury
to personnel. Do not drain fog oil
near open flames or while smoking.
NOTE
Drain fog oil from fog oil tank into
suitable container using drain hose
a. Remove plug valve (1) from nipple (2) on fog
oil tank (3) Remove nipple (2).
b. Clean thread in fog oil tank with a rag.
c. Coat threads of nipple (2) with sealing com-
pound.
d. Install nipple (2) in fog oil tank (3). Install plug
valve (1) on nipple (2).