TM 11-6625-3025-14/ET426-AA-MMA-010/E154 VII210/T.O. 33A1-8-902-1-1
Table 6-1. Troubleshooting
Trouble
Probable Cause
Remedy
1.
Indicator lamp
a.
Fuse
Replace fuse
not illuminated.
b.
Indicator lamp
Replace indicator lamp
Power switch in
ON position.
2.
Indicator lamp
+5V, -5V and 12V
Check +5V, -5V and
illuminated.
power supply defective
+12V power supply levels
All sync genera tor
(H drive, V drive
, blanking and sync
3.
No H drive,
a.
Replace drive/blanking
V drive, blanking
circuit card
b.
Pulse output circuit card
Replace pulse output
circuit card
4.
Pulse timing and
Pulse output circuit card
Adjust pulse output
format correct.
Amplitude
incorrect.
5.
H drive correct,
Sync count circuit card
Replace sync count
but V drive,
circuit card
blanking and sync
incorrect at
vertical rate
6.
H drive and/or
2:1 count
Replace sync count
horizontal rate
circuit card
blanking pulse
missing or occurs
at 2 H rate
7.
H drive or
Drive/blanking
Replace drive/blanking
horizontal rate
circuit card
circuit card
blanking pulses
have incorrect
width or are erratic
8.
V drive or vertical
a.
Sync count circuit card
Replace sync count
rate blanking
circuit card
pulses incorrect,
b.
Drive/blanking
Replace drive/blanking
but H drive and
circuit card
circuit card
are normal.
6-3