TM 11-6625-3041-12/TO 33A1-8-908-1
3-11. TROUBLESHOOTING PROCEDURE (cont)
If both indicators are lit before LAMP TEST is pressed:
Remove POWER SUPPLY access cover (refer to para 3-17) and note
which card contains a lit fault indicator. Replace that card
(if both cards contain a lit indicator, or if no card contains
a lit indicator, replace AC Input card A2), and repeat step 2.
If one indicator is lit before LAMP TEST is pressed:
Replace AC Input Card A2 (refer to para 3-17), and repeat step
2.
3-16