TM 3-1040-281-20&P
2
a. Place smoke generator (12)
cage mount (6).
NOTE
Top cage mount will not
fully seat to bottom cage
mount.
b. Position top cage mount (3) over smoke generator and install four screws (5). Tighten screws evenly to
maintain a level generator position. Working in a crisscross pattern, tighten each screw a few turns at a time
until a 5 foot-pound torque is obtained. Hold screws with wrench and install four locknuts (4).
NOTE
Step a. applies to left smoke generator only.
a. Secure fog oil inlet hose (2) to top cage mount (3) with tie down strap (1).
b. Route fog oil inlet hose (2) and fog oil exhaust hose (8) on inboard side of smoke generators between
smoke generator and cage mount leg (17) and then under rear retaining strap (18) of fog oil tank.
c. Connect fog oil inlet hose (2) on fog oil tank supply adapter (9) and fog oil exhaust hose (8) on fog oil tank
return adapter (10). Tighten fog oil hose clamps (7).
2-17