TM 3-1040-276-10
OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES (Cont)
Not Fully Mission
ITEM TO CHECK/SERVICE
Item
Capable If:
No.
Interval
Procedure
ENGINE ASSEMBLY
5
Float bowl will not move
a. Press adjustment knob (1) on float assembly and
Before
up or down, or lock in
check that float bowl (2) can be moved up or down,
place.
Release knob and check that float bowl locks in
place.
Float bowl toggle valve is
b. Check fuel control by gradually opening and closing
Before
float bowel toggle valve (3).
inoperative,
Change 1
2-8