TM 32-6625-022-24&P
Table 4-1. Voltage Test Points - Continued
Normal
Normal
Test
Test
point
condition
point
condition
+30 1 Vdc
TP 11
+200 Vdc
TP 3
TP 4
TP 12
+6.7 Vdc
+45 to +62 Vdc
+42 Vdc
TP 5
-32.5 Vdc
TP 401
TP 402
-28 Vdc
TP 6
-34 Vdc
-30 1 Vdc
+0.8 Vdc
TP 7
TP 403
+0.85 Vdc
TP 8
TP 404
-6.8 Vdc
Section Il. TOOLS AND EQUIPMENT
b. Tools and Test Equipment. The tools and test equip-
ment required and authorized for direct and general sup-
a. General. Refer to Maintenance Allocation Chart,
port maintenance are listed in the Maintenance Allocation
Appendix B,
and Repair Parts and Special
Tools List
Chart (MAC), Appendix D. Uses of these items are listed
(RPSTL), Appendix C, as they pertain to direct and general
support maintenance.
Table 4-2. Direct and General Support Maintenance Tools and Test Equipment
Use
Item
NSN
Perform direct and general support
Electronics Equipment
maintenance procedures.
Tool Kit TK-100/G
Electronics Equipment
Tool Kit TK-101 /G
Electronics Equipment
5180-00-957-0439
Tool Kit TK-105/G
measurements.
6625-00-553-4699
troubleshooting and alignment
procedures.
Perform voltage measurements.
VTVM (50423) (#3006)