TM 3-1040-276-10
CHAPTER 3
MAINTENANCE INSTRUCTIONS
Section I. LUBRICATION INSTRUCTIONS
Don't forget; keep your smoke generator clean and
3-1. LUBRICATION INSTRUCTIONS. These lubrica-
lubricated, even when it will not be used for a while.
tion instructions are mandatory. Lubricate as required
for ease of operation and preservation of moving parts.
a. Open front cover (1).
b. Lubricate hinge (2) and clamping
catch (3) with fog oil.
c. Close and latch front cover (1).
Section Il. TROUBLESHOOTING PROCEDURES
actions. If a malfunction is not listed or is not corrected
3-2. SCOPE.
by listed corrective actions, notify your supervisor.
a. The table (p 3-2) lists the common malfunctions
c. Before you use the troubleshooting table, be
you may find during the operation or maintenance of
sure you have performed all normal operating proce-
the M3A4 smoke generator or its components. Perform
dures, checks, and services.
the tests/inspections and corrective actions in the order
listed.
d. When operating in cold weather, see instruc-
b. This manual cannot list all malfunctions that may
occur, nor all tests or inspections and corrective
3-1